Software-Defined Automation for Water & Wastewater
Your SCADA, PLCs and radio links keep doing exactly what they do today. WaterWorksX Edge is the orchestration layer that unifies them at the edge, reading every field protocol, unifying the data in real time, and passing it straight back to your control room. No custom engineering required.
How It Works
Connectors write tags directly to a central local tag database. Every app and protocol reads from the same live source, so you can add new devices or services later without touching what is already running.
Built for reliability, simplicity, and low operational overhead.
Your SCADA master polls WaterWorksX Edge like a standard RTU. Device profiles auto-generate from live configurations, so the two always stay in sync.
Unify six field protocols into one common schema. Standardize setup across every site and share live tags over your existing radio network. Powered by the patent-pending WX Link bridge.
Alarms, compliance reporting, and intelligent monitoring all run locally. If the WAN connection drops, your plant keeps running without interruption.
Enable tag logging with a single click. Eliminates the cost, licensing, and complexity of dedicated third-party historians.
Access all tools, including embedded FactoryTalk apps, with one set of credentials and centralized certificate management (no browser security warnings).
Every live dashboard tags values with real-time status and age, giving operators complete confidence in the data they see.
Connect what you have. Share it wherever it is needed.
| Protocol | Capabilities & Features |
|---|---|
| DNP3 | Poll remote RTUs and serve data to SCADA. Operates as a master, outstation, router, and concentrator in a single service. WITS-oriented device profile. |
| DNP3 Tag Exchange | Share live tags site-to-site over existing radio links with event-driven updates and mesh routing. |
| EtherNet/IP | Direct integration with Allen-Bradley Logix platforms, featuring full online tag browsing and supervisory write-back. |
| Modbus TCP | Client polling for meters and drives, plus configurable register maps for upstream SCADA masters. |
| OPC UA | Read PLC tag structures and serve standardized tag databases to FactoryTalk Optix or external UA clients. |
| PROFINET / S7 | Native communication with Siemens S7-300, 400, 1200, and 1500 series PLCs. |
| Sparkplug B | Outbound mutual-TLS cloud connectivity with store-and-forward buffering that holds data through WAN outages until delivered. |
Independent micro-apps running on a single edge device.
Centralized access and system governance.
Polled independently to prevent slow field devices from blocking data flow.
Local history, intelligent alarming, and regulatory compliance.
Optional fleet expansion with zero local dependencies.
One Platform
The same image runs on every supported platform, so the device is a site decision, not a software one.




One image, one device.
Built-in OT security without administrative overhead.
Know exact data freshness at a glance.
Every field value maintains quality indicators from the sensor to regulatory reports.
| Status | Definition |
|---|---|
| Good | Telemetry is live and within poll window. |
| Bad | Field communications failure. |
| Stale | Data point exceeded expected update interval and was flagged automatically. |
Runs on standard industrial edge hardware (Edge Compute, HCC2,
OptixEdge).
One unified software image tailored per platform.
Deploy the same software stack regardless of your hardware vendor.
Browse PLCs or RTUs online and select the tags you need.
Map tags to outstations or cloud servers with auto-generated profiles.
Software updates are managed centrally and deployed only when you approve them.
Bring your existing SCADA, PLCs, and radio links exactly as they are. We will show you WaterWorksX Edge running live on your own network, on one site, before you decide anything.
Maximize efficiency, minimize downtime, and gain real-time control over your water and wastewater infrastructure. Contact us today to:
New Zealand:
136 Hutt Road, Wellington 5012, New Zealand
Request a walkthrough on the Allen-Bradley estate you already own.
We use cookies to understand how visitors use this site. Analytics cookies are only set if you accept them. You can change your choice at any time.
Manage your cookie preferences below:
Essential cookies enable basic functions and are necessary for the proper function of the website.
Statistics cookies collect information anonymously. This information helps us understand how visitors use our website.
Marketing cookies are used to follow visitors to websites. The intention is to show ads that are relevant and engaging to the individual user.
The LinkedIn Insight Tag (partner ID 9659748) is deployed through Google Tag Manager for retargeting and conversion measurement of WaterWorksX advertising on LinkedIn. It is gated on marketing/advertising consent and does not load unless that consent is granted.
Service URL: www.linkedin.com (opens in a new window)
You can find more information in our Cookie Policy and Privacy Policy.