Software-Defined Automation for Water & Wastewater

Your SCADA stays. WaterWorksX Edge does the rest.

WaterWorksX Edge reads your site data into one live tag database and serves it back to your control room like any other outstation. Add WX Central later if you want every site on one screen.

7
Field protocols supported out of the box
0
Changes to your existing SCADA
100%
On-site execution (internet optional)
1
Single login for all apps

Why WaterWorksX Edge?

Built to run unattended at a pump station for years.

Your SCADA Stays As It Is

Your SCADA polls it like a standard RTU.

The Same Setup at Every Site

One schema for every site, and HydroFlow shares tags between sites over your radio links.

Robust Data Plane

Lose the WAN and the site carries on.

Built-In Data Historian

One click turns on logging. No separate historian to buy.

One Login

One login for every app on the box, with no browser warnings.

Stale Data Is Flagged

Every value carries its status and age, all the way to SCADA and reports.

Connectivity

Everything below ships in the box.

ProtocolCapabilities & Features
DNP3 Master, outstation, router and concentrator. SAv5 per outstation. WITS PSA member, tested against IEEE 1815.
HydroFlow Site-to-site tag sharing over existing radio links. Event driven, and survives a restart.
EtherNet/IP Logix tag browsing, L5X import, and write-back with read-back.
Modbus TCP Polls meters and drives, and serves register maps to SCADA.
OPC UA Client and server, including FactoryTalk Optix.
S7 Comms Siemens S7-300, 400, 1200 and 1500. On 1200 and 1500, enable PUT/GET and use non-optimized data blocks.
HCC2 Reads the HCC2 tag database. No firmware change.
Sparkplug B One outbound mutual-TLS link, buffered through WAN outages.

The Modular Application Suite

Each app runs on its own, so one can be updated or restarted without touching the rest.

Device Manager

Setup, logging and alarms.

  • Configurator: apps, network, licensing and updates.
  • Data Points: the shared tag database.
  • Data Logger: trends and CSV export.
  • Alarms & Events: ISA-18.2 alarms with SMS and on-call escalation.
  • Network Diagnostics: traffic and data use.

Field Connectors

Each connector polls on its own, so one slow device never holds up the rest.

  • DNP3
  • EtherNet/IP
  • Modbus TCP
  • OPC UA
  • Siemens S7
  • HCC2

Operations & Analytics

Compliance, efficiency and answers, on the box.

  • Water Compliance: daily checks and a 12-month audit register.
  • Pump Efficiency: live efficiency against the pump curve.
  • Hydro: ask your plant questions in plain English, answered on the box.

Cloud Connection

What runs on the box for WX Central.

  • Fleet Bridge: buffered telemetry over one outbound connection.
  • Atlas Site Map: the site's comms map.

Optional

WX Central

The multi-site tier of WaterWorksX Edge: one place to see every site. Hosted by us, in your Azure tenancy, on your premises, or a mix.

See WX Central

One Platform

Runs on Your Hardware

The same software package runs on every supported platform, and each service updates on its own. The device is a site decision, not a software one.

WaterWorksX
Edge Compute industrial computer
Edge Compute
Rack / panel
HCC2 rugged edge controller
HCC2
Rugged edge
OptixEdge DIN-rail gateway
OptixEdge
DIN-rail gateway
SOON
LogixEdge controller
LogixEdge
Coming soon

One package, any supported device.

Live and operational in Australia and New Zealand. Real sites, real data, 24/7.

Built to the Margo specification (Preview Release 2) for orchestrated deployment. Built for LogixEdge, on the same package.

Secure by Construction

Security that is part of the build, not a project after it.

  • Every site has its own certificate, and the broker admits it to its own topics only.
  • DNP3 Secure Authentication on the SCADA link.
  • A control write needs an allow-listed mapping and the PLC's Local/Remote permission, and is read back.
  • Signed releases with a software bill of materials.

Data Quality & Status

What each status means, and where it goes.

StatusDefinition
Good Telemetry is live and within poll window.
Bad Field communications failure.
Stale Data point exceeded expected update interval and was flagged automatically.

Deployment

Runs on standard industrial edge hardware (Edge Compute, HCC2, OptixEdge).
The same package on every platform, with each service updated on its own.

01

Select Hardware

Edge Compute, HCC2 or OptixEdge.

02

Connect Field Devices

Browse PLCs and pick the tags you need.

03

Map & Export

Map tags to outstations. Profiles build themselves.

04

Join WX Central

Scan the label and the box appears in your Client Area.

Software updates are managed centrally and deployed only when you approve them.

Start with a Proof-of-Concept Site

Bring one site as it is. You see WaterWorksX Edge running live on your own network before you decide anything.

Modernize Your Water Network with WaterWorksX

Maximize efficiency, minimize downtime, and gain real-time control over your water and wastewater infrastructure. Contact us today to:

Email updates (optional)
Offices

New Zealand:
WaterWorksX Limited, 136 Hutt Road, Wellington 5012, New Zealand

United States:
WaterWorksX Inc., Austin, TX 78731, USA

Get In Touch

[email protected]

Call Us Now

+64 4 213 9750

↑